Section 6: Commissioning
February 2019
Step 7 - Manually move the actuator with the handwheel (see Section 3.1 or Section 3.5) or
by motor via the control switch (black button) to the end position OPEN of the valve.
Figure 19
Display Overview:
1.
Step 8 - When the desired end position OPEN of the valve is reached, move the selector
switch back to the middle position. Thus, the line "TEACHIN" disappears.
Figure 20
Figure 21
19
Absolute value: Absolute value of the position feedback.
Relative value: The value to the other end position.
Display (5)
1
Absolute value
Selector Switch in Neutral Position (4)
Display (6)
User Instructions