MAN-02-04-60-0351-EN Rev. 3
7.2.2
To provide users with better status information, basic status data is displayed using 4 color
LEDs. As the device powers up, it undertakes a self-test whereby all 4 LEDs briefly light up
simultaneously.
Figure 35
Table 2.
Description
L1
L2
L3
L4
Control Unit
LED Display
LED Display
L3
L5
LED Function Table
Colour
Lights up
Yellow
No torque error
Ready
Yellow
(operational
readiness)
Red
OPEN
Green
CLOSED
L4
L1
Flashes quickly
Flashes slowly
Torque fault
Path error (no
operational
readiness)
Applies upon
torque-dependent
opening:
Moving to
Occurs when the end
OPEN position
position OPEN is reached
but the
cut-out torque has not
yet been reached.
Applies upon
torque-dependent
Moving to
closing: Occurs when the
CLOSED
end position CLOSED is
position
reached but the cut-out
torque has not yet been
reached.
Section 7: Control Unit
Febraury 2019
L2
Does not light up
Error (no operational
readiness) motor
temperature, supply
voltage absent,
internal error
Actuator is not in the
open position.
Actuator is not in the
closed position.