Explanation Of The Atex Label - ProMinent Sigma 3 Basic Operating Instructions Manual

Diaphragm motor-driven metering pump
Table of Contents

Advertisement

Identity code
S3Ba Sigma 3 Basic type

1.1 Explanation of the ATEX label

Unit group
II
Units for use in areas with a potentially explosive atmosphere – excluding mines
Unit category
2
3
6
M
*** ATEX specification - refer to the nameplate on the pump, corre‐
sponding EU Declaration of Conformity for ATEX Machinery and
Ä Chapter 1.1 'Explanation of the ATEX label' on page 6
FPM = fluorine rubber
in accordance with Directive 2014/34/EU and standards EN ISO
80079-36, -37
High level of safety – use possible in zones 1 and 2
Normal level of safety – use possible in zone 2
modified*
* order-related design, refer to
order paperwork for pump
features
Electric power supply
_
Connection data - see motor nameplate
1
no motor, with B 5 flange, size 80 (DIN)
2
no motor, with C 56 flange (NEMA)
3
no motor, with B 5, size 71 (DIN)
Degree of protection
0
IP 55 (standard)
1
Exe design ATEX-T3 ***
2
Exd design ATEX-T4 ***
Stroke sensor
0
no stroke sensor (standard)
2
pacing relay (reed relay)
3
stroke sensor (Namur) for areas at
risk from explosion
Stroke length adjustment
0
manual (standard)
1, 2
Connection data - refer to
nameplate on servomotor
3 - 6 Connection data - refer to
nameplate on stroke control
motor

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S3ba

Table of Contents