Safety chapter
2.2 Explanation of the ATEX label
Explanation of the pump's ATEX labelling Makro TZ
Unit group
II
No mines or associated underground systems, which can be endangered by firedamp - Unit
for use in other areas at risk from explosion
Other parameters
3G Ex h
24
in accordance with Directive 2014/34/EU and standards EN ISO
80079-36, -37
(Example)
Explosion group
IIC
for explosion group IIC gas
- refer to your explosion protection document
IIB
for explosion group IIB gas
- refer to your explosion protection document
Temperature class
T3
for Temperature class T3 gas
- refer to your explosion protection document
T4
for Temperature class T4 gas
- refer to your explosion protection document
Equipment protection level (EPL)
Gb
high EPL
use possible in zones 1 and 2
- refer to your explosion protection document
Gc
normal EPL
use possible in zone 2
- refer to your explosion protection document
Suffix X
X
Special conditions - refer to the Declarations of Con‐
formity and EC-type examination certificates