Ignition hazard
Mechanically generated sparks from the mechanism with
low oil
Mechanically generated sparks from a faulty valve
Electrical stray current in the event of a short circuit
Electrical stray current in the event of a lightning strike
Static electricity
Electromagnetic waves (also lasers), ionising radiation
and ultrasound have an impact on the pump
Adiabatic compression and shock waves
Exothermic reaction, including the self-combustion of dust
Deposits of dust
Flammable feed chemicals
Ignition hazard with bought-in motor components
Protective measures to be observed by the customer
The customer must monitor and maintain the pump in
accordance with the "Maintenance" chapter.
The customer must monitor the capacity.
The customer must earth the pump and maintain the
earthing of the individual components.
The customer must put in place suitable protective meas‐
ures outdoors.
The customer must earth the earthing points and maintain
the potential equalisation cables of the individual compo‐
nents.
The customer must pay attention to potential equalisation
when dismantling.
Paint should not be applied too thickly.
Only clean plastic parts with a damp cloth.
Provide a temperature monitor on the dosing head with
feed chemical with critical friction properties.
The customer must wire the diaphragm rupture indicator in
such a way that it immediately stops the pump.
The customer must put in place measures in accordance
with EN 1127-1, if need be.
Feed chemical with electrical conductivity of < 50 pS/m,
which could form a combustible mixture: Do not allow the
unit to run dry – even when filling and emptying the liquid
end.
The pump is not suitable for use with substances that
have a tendency towards exothermic reactions or self-
combustion. Put in place measures in accordance with EN
1127-1, if need be.
Regularly clean the outside of the pump with a damp
cloth.
Only material version SS or TT is permitted to pump flam‐
mable feed chemicals.
Do not allow it to run dry.
The operator must install suitable protective measures, for
example a flow meter.
The customer must wire the diaphragm rupture indicator in
such a way that it immediately stops the pump.
Refer to the documentation for the motor.
Comply with the monitoring intervals.
The insulation resistance needs to be greater then 5
MOhm.
Provide a time-delay residual current device.
Provide overload protection by means of a motor protec‐
tion switch or an equivalent protective device.
Observe the minimum spacing between the air inlet on the
fan hood and any obstacles.
Avoid deposits of dust more then 5 mm deep.
Connect the earth wire.
Max. installation height: 1,000 m.a.s.l.
Safety chapter
17