Special conditions X

2.2 Explanation of the ATEX label

Unit group
II
Units for use in areas with a potentially explosive atmosphere – excluding mines
Unit category
2
3
2.
Fit the motor correctly on the flange (qualified personnel).
Observe the coupling operating instructions!
With a claw coupling: The claw on the motor shaft must be fixed at
the correct height, see corresponding figure and table.
3.
As you have converted an "incomplete machine" into a complete
machine, you must perform a conformity assessment, risk assess‐
ment, issue an EC Declaration of Conformity, fit your own company
nameplate, ... .
4.
With ATEX pumps: additionally perform an ignition hazard assess‐
ment.
5.
Complete the pump documentation / operating instructions.
The Declarations of Conformity can be found at the end of the operating
instructions.
If there is an "X" at the end of the ATEX specification of a unit in a "Decla‐
ration of Conformity for ATEX Machines" or a "Declaration of Incorporation
for ATEX Machines", then special conditions apply for the safe operation
of the equipment in areas at risk from explosion.
Please refer in this respect to the operating instructions, design test certifi‐
cates and other documentation for the bought-in parts!
in accordance with Directive 2014/34/EU and standards EN ISO
80079-36, -37
High level of safety – use possible in zones 1 and 2
Normal level of safety – use possible in zone 2
Type of explosive atmosphere
G
Mix of air and gases, vapours or mist
Areas at risk of explosion label
Ex
in accordance with EN ISO 80079-36, -37
Type of protection
h
non-electrical device
Explosion group
WARNING!