Safety chapter
Explanation of the pump's ATEX labelling Sigma S3Ba
Unit group
II
No mines or associated underground systems, which can be endangered by firedamp - Unit for use in
other areas at risk from explosion
Other parameters
3G Ex h
24
(Example)
Explosion group
IIC
for Group IIC gas
- Refer to the material safety data sheet for the gas or, for example,
Ä Tab. 2 'Example of the division of gases into explosion groups and temperature
classes' on page 25
IIB
for Group IIB gas
- Refer to the material safety data sheet for the gas or, for example,
Ä Tab. 2 'Example of the division of gases into explosion groups and temperature
classes' on page 25
Temperature class
T3
for Temperature class T3 gas
- Refer to the material safety data sheet for the gas or, for example,
Ä Tab. 2 'Example of the division of gases into explosion groups and
temperature classes' on page 25
T4
for Temperature class T4 gas
- Refer to the material safety data sheet for the gas or, for example,
Ä Tab. 2 'Example of the division of gases into explosion groups and
temperature classes' on page 25
Equipment protection level (EPL)
Gb
high EPL in normal operation and in the event of expected errors;
use possible in zones 1 and 2
- refer to your explosion protection document
Gc
normal EPL in normal operation;
use possible in zone 2
- refer to your explosion protection document
Suffix X
X
Special conditions - refer to the Declarations of Conformity
and EC-type examination certificates