Technical data

15
Technical data
Only with "M - modified" design:
15.1

Performance data

S3Ba with 50 Hz operation
Type
Minimum pump capacity at maximum
back pressure
bar
120145 PVT
10
120145 SST
12
120190 PVT
10
120190 SST
12
120270 PVT
10
120270 SST
12
120330 PVT
10
120330 SST
12
070410 PVT
7
070410 SST
7
070580 PVT
7
070580 SST
7
040830 PVT
4
040830 SST
4
041030 PVT
4
041030 SST
4
68
WARNING!
Risk of personal injuries
Please observe the "Supplement for modified version" at
the end of the chapter!
It replaces and supplements the technical data!
l/h
ml/stroke
146
33.7
146
33.7
208
33.7
208
33.7
292
33.8
292
33.8
365
33.8
365
33.8
410
95.1
410
95.1
580
95.1
580
95.1
830
95.1
830
95.1
1030
95.1
1030
95.1
Performance data for TTT, PPT or PCT see type PVT
All figures refer to water at 20 °C.
The suction lift applies to a filled suction line and filled liquid end - when
installed correctly.
Maximum
Suction lift
stroke rate
Strokes/min
m water
column
72
5
72
5
103
5
103
5
144
5
144
5
180
5
180
5
72
4
72
4
103
4
103
4
144
3
144
3
180
3
180
3
Permissible
Connector
priming pres‐
size
sure, suction
side
bar
R"-DN
2
1 1/2" -
DN25
2
1 1/2" -
DN25
2
1 1/2" -
DN25
2
1 1/2" -
DN25
2
1 1/2" -
DN25
2
1 1/2" -
DN25
2
1 1/2" -
DN25
2
1 1/2" -
DN25
1
2" - DN32
1
2" - DN32
1
2" - DN32
1
2" - DN32
1
2" - DN32
1
2" - DN32
1
2" - DN32
1
2" - DN32

Hide quick links: