WARNING!
ATEX pumps in areas at risk from explosion
If feed chemicals are metered, which tend to produce
exothermic reactions or self-ignite (examples of exo‐
thermic reactions: pyrophoric substances with air, alkali
metal with water, decomposition of organic peroxides,
polymerisation reactions), they can lead to high tempera‐
tures and ignition.
Put in place measures in accordance with EN
80079-38.
WARNING!
ATEX pumps in areas at risk from explosion
If abrasive media is being metered, it will escape as
soon as all layers of the diaphragm have eroded
through.
Wire the electrical diaphragm rupture indicator to
stop the pump in the event of a diaphragm rupture.
WARNING!
ATEX pumps in areas at risk from explosion
Electrically wire all electrical units cleanly and per‐
manently to an electrically clean earthing point, -
e.g. with an earthing bar on your system.
Electrically connect the electrical units fitted with a
potential equalisation cable to each other, cleanly
and permanently, to an electrically clean potential
equalisation point - e.g. with a potential equalisation
bar on your system.
Note the enclosed documentation for the individual
electrical components.
WARNING!
ATEX pumps in areas at risk from explosion
Use a suitable motor protection switch to protect
power end motors. Use motor protection approved
for this application with Ex"e" motors. (Protection
against warming caused by overloading)
Provide a time-delay residual current device.
Observe the enclosed operating instructions for the
Ex motor.
WARNING!
The following applies in areas at risk from explosion:
Note the details of the type examination certificate
PTB 00 ATEX 2048 X for the Namur sensor
NJ1.5-8GM-N as well.
Safety chapter
19