Explanation Of The Atex Label - ProMinent Hydro 2 Series Operating Instructions Manual

Metering pumps
Table of Contents

Advertisement

Safety chapter
Declarations of Conformity for the pump
Special conditions X

2.2 Explanation of the ATEX label

Explanation of the pump's ATEX labelling Hydro
Unit group
II
No mines or associated underground systems, which can be endangered by firedamp - Unit for use in
other areas at risk from explosion
Other parameters
3G Ex h
26
2.
Fit the motor correctly on the flange (qualified personnel).
Observe the coupling operating instructions!
With a claw coupling: The claw on the motor shaft must be fixed at
the correct height, see corresponding figure and table.
3.
As you have converted an "incomplete machine" into a complete
machine, you must perform a conformity assessment, risk assess‐
ment, issue an EC Declaration of Conformity, fit your own company
nameplate, ... .
4.
With ATEX pumps: additionally perform an ignition hazard assess‐
ment.
5.
Complete the pump documentation / operating instructions.
The Declarations of Conformity can be found at the end of the operating
instructions.
If there is an "X" at the end of the ATEX specification of a unit in a "Decla‐
ration of Conformity for ATEX Machines" or a "Declaration of Incorporation
for ATEX Machines", then special conditions apply for the safe operation
of the equipment in areas at risk from explosion.
Please refer in this respect to the operating instructions, design test certifi‐
cates and other documentation for the bought-in parts!
in accordance with Directive 2014/34/EU and standards EN ISO
80079-36, -37
(Example)
Explosion group
IIC
for explosion group IIC gas
- refer to your explosion protection document
IIB
for explosion group IIB gas
- refer to your explosion protection document
Temperature class
T3
for Temperature class T3 gas
- refer to your explosion protection document
T4
for Temperature class T4 gas
- refer to your explosion protection document
Equipment protection level (EPL)
WARNING!
EX is relevant in areas at risk from explosion!

Hide quick links:

Advertisement

Table of Contents
loading