Functional description

5.4 Multi-layer safety diaphragm

30
1
2
3
4
5
Fig. 8: Integral relief valve
1
Spring, large
2
Ball
3
Rotary dial
4
Spring, small
5
Hose connection
With visual diaphragm rupture sensors, in the event of a diaphragm rup‐
ture, the lowered red cylinder (6) springs forward beneath the transparent
cover (7) so that it then becomes clearly visible - see Fig. 9.
With the electrical diaphragm rupture sensor, a switch is switched. A sig‐
nalling device must be connected to signal the diaphragm rupture.
Fig. 9: Visual diaphragm rupture sensor, triggered and untriggered
P_SI_0019