Stroke Actuator; Stroke Control Drive; Diaphragm Rupture Sensor - ProMinent Sigma 3 Basic Operating Instructions Manual

Diaphragm motor-driven metering pump
Table of Contents

Advertisement

15.7

Stroke actuator

15.8

Stroke control drive

15.9

Diaphragm rupture sensor

a) Contact (standard with identity code
specification "Displacement mechanism":
A)
a) Namur sensor (for identity code specifi‐
cation "Displacement mechanism": A)
Voltage
Mains frequency
85 ... 265 V AC
50/60 Hz
Voltage
Mains frequency
85 ... 265 V AC
50/60 Hz
Install the sensor in accordance with the chapter "Instal‐
lation, electrical".
Tab. 7: Contact loading, max.
with voltage
Maximum current
30 V DC
1 A
The diaphragm rupture sensor is an N/C.
For safety reasons we recommend connection to
protective low voltage, e.g. in accordance with EN
60335-1 (SELV).
The cable can be connected as required.
Install the sensor in accordance with the chapter "Instal‐
lation, electrical". Refer to its documentation.
Sensor name: NJ1.5-8GM-N.
5–25 V DC, in accordance with Namur or DIN 60947-5-6, potential-free
design.
Data
Nominal voltage *
Power consumption - active surface
uncovered
Power consumption - active surface cov‐
ered
Rated switching distance
* Ri ~ 1 kΩ
Technical data
Capacity
11.7 W
Capacity
6.5 W
Value Unit
8 VDC
> 3 mA
< 1 mA
1.5 mm
73