Short Description - AUMA AC 01.2 Manual

Actuator controls
Hide thumbs Also See for AC 01.2:
Table of Contents

Advertisement

Actuator controls
AC 01.2/ACExC 01.2
Serial number
Actuator controls termin-
al plan
AUMA power class for
switchgear
Control
Data Matrix code
2.2.

Short description

Actuator controls
Local con-
trols/AUMA CDT
Table 1: Description of serial number (with example)
05
14
MD12345
Position 1+ 2: Assembly in week
05
Week 05
Position 3 +4 : Year of production
14
Year of production: 2014
All other positions
MD12345
Internal number for unambiguous product identification
Position 9 in the TPA wiring diagram: Position transmitter (actuator):
Control unit: electromechanical:
0 = Without position transmitter
A, B, J, K, L, N = Potentiometer
C, D, E, G, H, M, S = EWG/RWG (electronic position transmitter)
Control unit: electronic:
I = MWG (Magnetic limit and torque transmitter)
The switchgear used in the actuator controls (reversing contactors/thyristors) are
classified according to AUMA power classes (e.g. A1, B1, ....). The power class
defines the max. permissible rated power (of the motor) the switchgear has been
designed for. The rated power (nominal power) of the actuator motor is indicated in
kW on the motor name plate. For the assignment of the AUMA power classes to the
nominal power of the motor types, refer to the separate electrical data sheets.
For switchgear without assignment to any power classes, the actuator controls name
plate does not indicate the power class but the max. rated power in kW.
Table 2: Control examples (indications on controls name plate)
Input signal
Description
24 V DC
Control voltage 24 V DC for OPEN - CLOSE control via digital inputs
(OPEN, STOP, CLOSE)
115 V AC
Control voltage 115 V AC for OPEN - CLOSE control via digital inputs
(OPEN, STOP, CLOSE)
0/4 – 20 mA
Input current for setpoint control via analog input
When registered as authorised user, you may use the AUMA Support App to scan
the Data Matrix code and directly access the order-related product documents without
having to enter order number or serial number.
Figure 3: Link to the App store:
AUMATIC actuator controls are used to operate AUMA actuators and are supplied
ready for use. The controls may be mounted directly to the actuator or separately
on a wall bracket.
The functions of the AUMATIC controls include standard valve control in OPEN -
CLOSE duty, positioning, process control, logging of operating data right through to
diagnostic functions.
Operation, setting, and display can be performed on site directly at the controls.
When set to local control, it is possible to
Identification
11