Terms - Mitsubishi Electric MELSEC iQ-R AnyWireASLINK User Manual

Master module
Table of Contents

Advertisement

TERMS

Unless otherwise specified, this manual uses the following terms.
Term
Address
Address writer
AnyWireASLINK
Buffer memory
Device
Engineering tool
ID
Intelligent device station
Intelligent function module
Label
Link device
Master station
Module label
Power cable (24V, 0V)
Terminating unit
Transmission cable (DP, DN)
Transmission cycle time
14
Description
A setting value assigned to a slave module to identify each node on the AnyWireASLINK network
A hand-held device to read/write device parameters (including addresses) from/to a slave module
A reduced wiring network where sensors at the end of a control system are connected to a programmable
controller.
This network enables a master module to detect sensor disconnection and enables a user to set the I/O
operations of an AnyWireASLINK system on the RJ51AW12AL from the upper system without using the I/O
areas of the CPU module.
Memory in an intelligent function module for storing data such as setting values and monitored values.
A device (X, Y, M, D, or others) in a CPU module
Another term for the software package for the MELSEC programmable controllers
A parameter to identify whether the module is an input module or output module based on its address
A station that exchanges I/O signals (bit data) and I/O data (word data) with another station by cyclic
transmission. This station responds to a transient transmission request from another station and also issues a
transient transmission request to another station.
A module that has functions other than input and output, such as an A/D converter module and D/A converter
module
A label that represents a device in a given character string
A device (RX, RY, RWr, or RWw) in a module on CC-Link IE Field Network
A station that controls the entire network. This station can perform cyclic transmission and transient transmission
with all stations. Only one master station can be used in a network.
A label that represents one of memory areas (I/O signals and buffer memory areas) specific to each module in a
given character string.
For the module used, GX Works3 automatically generates this label, which can be used as a global label.
A cable that connects 24VDC external power supply to the RJ51AW12AL.
This cable is also used when the isolation (4-line) type slave module and RJ51AW12AL are connected.
A waveform shaper
A signal cable that connects between a slave module and the RJ51AW12AL
A data sampling interval

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r seriesMelsec iq anywireaslink rj51aw12al

Table of Contents