Details of the output signal

The following shows the on/off timing or condition of the output signal.
Error flag clear command: Y0
When 'Error flag clear command' (Y0) is turned off and on, the following input signals and the buffer memory areas are
cleared.
Type
Input signal
Buffer memory area
Resetting the CPU module or turning off and on the power supply also clears the input signals and the buffer memory areas
shown above.
Automatic address detection command: Y1
Turn on this signal to execute automatic address detection.
Overlap address inspection command: Y2
Turn on this signal to execute same address used check.
AnyWireASLINK version compatibility inspection command: YD
Turn on this signal to execute the AnyWireASLINK version compatibility inspection.
Parameter access request command for the slave module: Y10
Turn on this signal to perform the following operations from the RJ51AW12AL to a slave module.
• Read and write the parameter of the slave module.
• Execute the remote address change function.
Parameter batch read command for the slave module: Y11
Turn on this signal to collectively read parameters from all slave modules that the RJ51AW12AL recognizes.
Parameter batch write command for the slave module: Y12
Turn on this signal to collectively write parameters to all slave modules that the RJ51AW12AL recognizes.
Item
• 'DP/DN short error' (X1)
• '24V/DP short error' (X2)
• 'Transmission cable voltage drop error' (X3)
• 'DP/DN disconnection error' (X4)
• 'AnyWireASLINK version compatibility inspection error' (X8)
• 'Backup/Restore unsupported error' (X9)
• 'Slave module alarm signal' (X10)
• 'Parameter access error' (X12)
• 'Number of the error IDs' (Un\G8192)
• 'Error ID information storage area' (Un\G8193 to Un\G8320)
• 'Error ID information bit area (bit output)' (Un\G8704 to Un\G8719)
• 'Error ID information bit area (bit input)' (Un\G8736 to Un\G8751)
• 'Error ID information bit area (word output)' (Un\G8768 to Un\G8799)
• 'Error ID information bit area (word input)' (Un\G8800 to Un\G8831)
• 'Number of the alarm IDs' (Un\G9984)
• 'Alarm ID information storage area' (Un\G9985 to Un\G10112)
• 'Latest error code storage area' (Un\G10256)
• 'Latest error ID storage area' (Un\G10257)
• 'Event code for sub information area' (Un\G12096)
• 'Sub information area' (Un\G12097 to Un\G12224)
Operation
The input signal is
turned on and off.
Zero is stored as the
value of the buffer
memory area.
APPX
93
Appendix 2 I/O Signals