Figure 10-8: Example Of A Function Test For The Safety System Using The Online - Leuze electronic MSI 200 Series User Manual

Configurable safety modules and safe extension modules
Table of Contents

Advertisement

Leuze electronic
3.
Switch the MSIsafesoft configuration software to online mode by clicking on
the "Display online values" icon in the toolbar.
Signal lines and function block connections are now displayed in the connection editor
in different colors, according to their state (TRUE/FALSE), and together with the current
values. The hardware editor also supports the function test through "lit" LEDs.
4.
Trigger a safety demand via the safe command devices.
5.
Monitor the response of the machine and the configuration via the online values in the con-
nection editor.
Example:
E-Stop not pressed, no
safety demand
Safety demand
Figure 10-8
Example of a function test for the safety system using the online mode of
MSIsafesoft
Configuration and commissioning
MSI 100/200
88