Safe digital outputs O0 to O3 and ground-switching outputs O0- and O1-
Limiting continuous current
Maximum output voltage in low state
Maximum leakage current in low state
WARNING: Loss of the safety function
Switching of the load at maximum leakage current can lead to the loss of the safety function.
Note that the load does not switch at this current and must not remain in the switched-on state.
Take this into account when selecting the actuator.
Load
1
Capacitive
2
Inductive
Test pulses
Protective circuit
Short circuit protected
Status indicator
1
When using electromechanical components (e.g., contactors), the capacitive load can be disregarded.
2
Use a suitable and effective protective circuit on inductive loads.
Clock outputs T0 and T1
Quantity
Type
Voltage
Limiting continuous current
Test pulses
Short circuit protected
Signal outputs M0 to M3
Quantity
Type
Voltage
Limiting continuous current
Short circuit protected
Times
Reaction time
Recovery time
Leuze electronic
2 A (each channel, see Derating)
2 A (total current of all outputs)
< 5 V
2 mA
Max. 1 μF (electronic components)
- (see protective circuit)
< 1 ms
Yes, within the scope of the operating voltage limits
Yes
4 x green LEDs (1 LED per output)
2
Digital
24 V DC (supply via 24V/0V)
100 mA
< 1 ms
Yes
4
Digital
24 V DC (supply via 24V/0V)
100 mA
Yes
Max. 30 ms (plus reaction time of MSI-EM200-4RO)
See appendix "Switch-off time of the MSI 100/200 system" on page 124.
< 10 s