Firmware update

Validation / 
verification
Leuze electronic
Update the firmware of the MSI 100/200 system with the help of the MSIsafesoft safe config-
uration software.
8.1

Safety notices for the firmware update

The following safety notices must be observed during and after the firmware update:
WARNING: Non-safe operation
While the firmware update is running, the MSI 100/200 operates in the non-safe mode. Reli-
able detection of the safety demand is not guaranteed while in this operating state.
Therefore, make sure that running the firmware update will not lead to any hazardous
situations.
Take action to prevent the machine from being started up unintentionally (by, e.g., dis-
connecting the terminals on the output side from the MSI 100/200 system, and discon-
necting the drives from the power supply).
ATTENTION: Module defect
Interrupting the connection between the PC and safety module during the firmware update
can damage the device.
A faulty or incomplete firmware installation can render communication between the PC and
safety module impossible. In this case, the faulty installation cannot be corrected with the
assistance of MSIsafesoft.
Do not disconnect the USB cable during the update process.
Do not switch off the safety module during the update process.
Once the firmware update has concluded, validate and verify the safety application.