MSI 100/200 system
MSI 100 and 
MSI 200
MSI-EM200-8I4IO
MSI-EM200-4RO
Leuze electronic
1.3

Range of application of the product

Only use the MSI 100/200 system in accordance with the range of application described in this
chapter.
1.3.1

Intended use

Only use the safety modules and safe extension modules of the MSI 100/200 system accord-
ing to the information provided in this section.
The intended use of the MSI 100/200 system is safe shutdowns. Safe switch-on is not an
intended use.
All modules of the MSI 100/200 system are intended for use in the industrial sector.
The safety modules and safe extension modules can only perform their safety-relevant tasks
if they have been integrated in the execution process correctly and in such a way as to avoid
errors.
You must observe all information in this user manual as well as in the user manuals and online
help listed in "Documentation" on page 14.
Only use the modules of the MSI 100/200 system according to the provided technical data. 
See chapter 14 „Technical data and ordering data" from page 101.
You can find further information on the use of the MSI 100/200 system under "Using the sys-
tem" on page 18.
The MSI 100 and MSI 200 modules are configurable safety modules with 20 safe inputs and
four safe outputs. The inputs are used for the evaluation of safety-relevant transducers, such
as E-Stop buttons or safety doors. The circuits are interrupted in a safe manner via the outputs.
In addition, four signal outputs, two clock outputs and two ground-switching outputs are avail-
able.
The MSI 100 safety module is a stand-alone device and cannot be extended with safe exten-
sion modules.
The MSI 200 safety module can be extended with safe inputs and outputs using safe extension
modules of the MSI 100/200 system.
You can connect one gateway to both safety modules for transferring diagnostic data.
The MSI-EM200-8I4IO safe extension module is an extension to the MSI 200 safety module.
An additional four configurable inputs or outputs, two configurable clock or signal outputs as
well as eight safe inputs are thereby made available.
The MSI-EM200-4RO safe extension module is an extension to the MSI 200 safety module.
An additional four safe relay outputs and four signal outputs are thereby made available.