Stop category 1 only in the
error-free state
Operating duration in
faulty state
Leuze electronic
2.5
Error detection
Depending on the wiring and the configuration, the safety modules and safe extension mod-
ules of the MSI 100/200 system detect the following errors at the safe inputs and outputs:
–
Short circuit of the outputs
–
Cross-circuit of the inputs or outputs
–
Overload at the outputs
2.6
Error state
ATTENTION: Property damage through immediate shutdown
The device ensures stop category 1 only in error free operation. If the supply voltage is lost
or in the case of an internal error, the device behaves acc. to stop category 0.
Do not use the device in applications in which stop category 1 must be maintained even
•
in case of failure.
WARNING: Loss of the safe state in the error state
While in the error state, no module-internal tests run and, due to an accumulation of errors,
the safe state may be exited.
If the module takes on a faulty state, examine, acknowledge or rectify the error within 72
•
hours.