Audit Trial Configuration Items - Honeywell CNI4 Operating And Installation Manual

Table of Contents

Advertisement

9 Appendix
Item Name
Ch Item #
Default = 12:00:00
204
Date
Default = 01-01-99,
Format: MM-DD-YY
205
Gas Day Start Time
Default = 09 00 00
262
Date Format
Select :
0 - MM-DD-YY Default
1 - DD-MM-YY
2 – YY-MM-DD

9.1.5 Audit Trial Configuration Items

Item Name
Ch Item #
450
Memory Capacity
481
Audit Trail Max Records
258
Audit Trail Data Item 1 of 10
Default: 002 (Ch1Accumulated
Volume)
259
Audit Trail Data Item 2 of 10
Default: 226 (Ch1 Inc.
Accumulated Volume)
260
Audit Trail Data Item 3 of 10
Default: 910 (Ch2Accumulated
Volume)
24-hour "military" format, i.e., 14:30:02 would be two seconds
past 2:30 PM. When entering or changing the time, leading
zeros are required where applicable.
A numeric field indicating the calendar date provided by the
on-board real-time clock. The format of the Date is
determined by the selection at item 262 and may be
displayed as MM-DD-YY, DD-MM-YY, or YY-MM-DD. The
Date automatically tracks the days in the month, including
leap year. When configuring this item, leading zeros are
required where applicable. This Date and Time (from Item
203) are used to time-stamp the records in Audit Trail
memory.
User selectable time to indicate the beginning of the GAS
DAY, which by definition for other items, is the time of day
when daily computations are re-zeroed to begin the next
day's computations. Note: The time entered should only
contain zeros for minutes and seconds.
Codes (0-2) to select the format in which the Date is entered
and displayed at item
204. The format for all date-related items will also be
governed by this item
A read-only value indicating audit trail memory
capacity, expressed in days or months, based on
the maximum number of audit trail records at item
481.
A read-only value indicating the maximum number
of audit trail records available for this particular
product
The first of ten user selectable Audit Trail Report
Items that can be configured for Audit Trail logging.
To use these ten items, insert the desired item code
number into any of the report locations (258 - 261
and 229 - 234). The value "255" at any of these
Report Items will cause that position to be 'blank'.
Description
Description
Honeywell
| 57

Advertisement

Table of Contents
loading

Table of Contents