Honeywell CNI4 Operating And Installation Manual page 67

Table of Contents

Advertisement

9 Appendix
Item
Item Name
#
3007
Modem Power
Source Type
3008
Battery Charge
Capacity
3009
Super Cap Low
voltage to drop the
call
3011
Available % battery
life
3012
Super Cap Charge
Availability (in sec)
3014
Modem Internal
Voltage
3016
Fetch radio
parameters
3017
SSL enable /
Disable
3021
Modem IP Type
3022
Packet Service
Connection
Command
3023
Access Point Name
3024
PAP / CHAP Enable
3025
PAP / CHAP User
Nam
3026
PAP / CHAP Pass
Word
Item Description
Automatically detected by cloudlink and updated
when 3005 is resetted
Battery Charge Capacity: is based on battery type
(0 if external Power Supply is used)
Super cap voltage reading. If event occurs, it will
be logged in the diagnostics.
Percentage battery life
Super cap voltage in seconds. Before calling the
EC350 will read this parameter and decide whether
it can make a call or not.
Internal Voltage supply to the modem. Should be in
the x-xV range
Forces a read of the SIM card details upon modem
power up (reads SIM#, Radio carrier, Radio
software version, radio hardware version).
0 - Disable, 1 - Enable
TCP/IP configuration to be used
This command initiates a packet (internet)
connection This can be different for different
cellular providers, but generally the universally-
accepted string is"ATD*99#"
This is the name of the gateway to the service
provider's internet service. Examples: m2m@T-
Mobile.com or isp.singular
Password Authentication protocol or
Challenge/Handshake Authentication Protocol.
Additional security settings for the cellular
connection.
Possible Values
0 - Single Battery
Pack, 1 - Dual
Battery Pack, 2 -
Quad Battery Pack,
3 - One Battery
With SuperCap, 4 -
External Supply
With Single Battery
Pack, 5 - External
Supply With Dual
Battery Pack, 6 -
External Supply, 7 -
No Supply.
Floating Point
value (in Milli
Coloumbs)
Floating Point
value, Min = 2 V
Max = 4 V
Min = 0 % Max =
100 %
Floating Point
value (in Sec)
Floating Point
value (In Volts)
0 - Clear, 1 - Set.
0 - Disable, 1 -
Enable.
0 - IPV4, 1 - IPV6, 2
- IPV4V6.
49 character string
49 character string
0 - None, 1 - PAP, 2
- CHAP.
29 character string
29 character string
Honeywell
| 63

Advertisement

Table of Contents
loading

Table of Contents