Honeywell CNI4 Operating And Installation Manual page 70

Table of Contents

Advertisement

9 Appendix
Item
Item Name
#
3076
BLE MAC Address
3078
Advertisement
interval(in msec)
3079
BLE Module Status
3080
BLE firmware
version
3081
BLE stack version
3082
BLE forget all
bonds
3084
BLE Last RSSI
3085
BLE Security type
3086-
Modem SSL
3093
Security Passphrase
3095
Remote Unit ID
(RUID)
3096
Running / Existing
Firmware Version
3097
Running Firmware
CRC checksum
3098
Down Loading
Firmware Version
3099
Firmware upgrade
max packet size
Item Description
How often Cloud Link broadcast its ID.
Shows if a device is connected to Cloud Link over
the BLE link.
Cloud Link remembers up to 8 devices that have
paired with it. Once this limit is reached no new
device can be connected. This parameter has to be
Enabled to clear the list of paired devices and be
able to pair a new device. This parameter can be
changed either using an already paired
smartphone or by going into level 2 "FORGET DEV"
menu.
There are 2 types of connection : "Just Works" and
"Passkey Entry". With Just Works, any device can
connect to the modem over BLE, no passkey is
required. If "Passkey entry" is selected, when trying
to connect, a passkey has to be entered on the
smartphone to be able to pair. This passkey can be
found on the EC350 in Level 2, "BT PAIRING" menu.
The passkey must be entered within 40 seconds.
The passkey is valid for 40 seconds after which it
expires. If the passkey expires, you need to obtain
a new passkey, and start all over. Passkey entry
bluetooth pairing works only when the Cloud Link
4G Modem is used in integrated mode.
When SSL secure connection is used, a password
has to be entered on both ends (Cloud Link and
MasterLink) so that the communication can be
established. This passphrase is used to encrypt the
security certificate.
Used for BLE idvertisment and identification of
Cloud Link (Standalone) in MasterLink.
Cloud Link 4G Modem firmware revision
Cloud Link 4G Modem firmware checksum
Firmware version being downloaded to the Cloud
Link.
Maximum packet size used during firmware
upgrade. When doing a Firmware upgrade over the
Possible Values
String
16 bit integer Min =
320 mSec Max =
10000 mSec
0 - Disconnected, 1
- Connected.
String
String
0 - Disable, 1 -
Enable.
Floating point
value(in dBm)
1 - Just Works, 2 -
Passkey Entry.
Passkey entiry is
not applicable for
CNI4.
String
String, 6 characters
String
String
String
0 - 256 Bytes, 1 -
512 Bytes, 2 - 1024
Bytes.