Honeywell CNI4 Operating And Installation Manual page 72

Table of Contents

Advertisement

9 Appendix
Item
Item Name
#
3114
Cloud Link 4G
Modem board
temperature
3118
Cloud Link 4G
Modem Reset
counter
3120
Low Battery Alarm
Event
3121
Modem Magnetic
Alarm
3122
BLE transmit power
3123
BLE enable
3124
Last call Cellular
service
3125
Last call cellid
3126
Last call Location
ID
3127
Last call RSCP
3128
Last call RSRQ
3129
Last call MCC
3130
Last call MNC
3131
Last call Physical
cell id
3132
Last call Cellular
RSRP
3133
Last call Cellular
Item Description
be able to write to that parameter, first disable the
count feature (item 3136), then write item 3113,
then enable the pulse count feature (item 3136).
Modem Board Temperature (units are defined in
item 3140)
This items keeps track of how many times the
modem has been rebooted.
The battery alarm depends on the number of days
(defined in 3006) before the battery is expected to
die. If 3105 is set, this will generate a call to
PowerSpring. This alarm will be active and can be
acknowledge by clearing this alarm.
Whenever Magent is swiped on the magnetic reed
switch, this alarm will be active and can be
acknowledge by clearing this alarm. If 3106 is set,
this will generate a call to PowerSpring.
BLE transmit power
If Disabled, this item will turn off the BLE module
completely.
Last call Cellular service
Last call Cellular ID Global cellular identification
number-Region specific.
Last call location identifier. Set of Cell Towers
Identification ID in 4G
RSCP - Receive Signal Coded Power. Signal
Strength, used on 3G networks. Excellent : -50dBm
ð -70dBm Good : - 70dBm ð -85dBm Fair : -85dBm
ð -100dBm Poor : -100dBm ð -120dBm
RSRQ - Reference Signal Receive Quality. Quality
of the signal received on a 4G network.
MCC - Mobile Country Code. Allows Country
identification.
MNC - Mobile Network Code. Cellular Operator
Identification.
Actual Tower Identification number
RSRP - Reference Signal Receive Power Signal
Strength on 4G networks. Excellent : -70dBm ð -
90dBm Good : - 90dBm ð -105dBm Fair : -105dBm
ð -120dBm Poor : -120dBm ð -150dBm
TAC - TowerArea Code Set of Cell Towers
Possible Values
Float
Usigned integer 32
bits
0 - Not Active, 1 -
Active.
0 - Not Active, 1 -
Active.
16 bit integer Min =
0 Max = 9
0 - Disable, 1 -
Enable.
0 - 2G, 1 - 3G, 2 -
4G, 3 - No Call.
String
String
Floating point
Value (in dBm)
Floating point
Value (in dBm)
Usigned integer 32
bits
Usigned integer 32
bits
String
Floating point
Value (in dBm)
String
Honeywell
| 68

Advertisement

Table of Contents
loading

Table of Contents