1 Introduction
Additionally, each pulse channel may also be configured to receive a user-specified FixedFactor
multiplier. By default, this multiplier is disabled but may be activated by inserting the desired factor into
item 044 for Ch1 and item 440 for Ch2. The FixedFactor feature is normally used to adjust the
accumulated uncorrected volume for a fixed pressure factor or fixed temperature factor (or both).
The number of digits for Accumulated Volume and FixedFactor Volume can also be assigned for both
channels. (item numbers 097, refer to
Table 1-2
FixedFactor Volume
Incremental FixedFactor Volume
FixedFactor Value
FixedFactor Volume Units
FixedFactor Volume Digits
Scaling related Item Numbers
: Quick Reference: Items associated with FixedFactor Volume
in the Appendix section.)
Ch1 Item#
000
225
044
090
096
Ch2 Item#
908
909
440
457
096
Honeywell
| 2