9 Appendix
Item
Item Name
#
TAC
3134
Last call duration
3135
Last call status
3136
Pulse count enable
3137
Modem
Restore/Reset/Clear
logs
3138
Modem server
timeout
3139
Remote Unit ID 2
(RUID)
3140
Temperature units
3141
BLE number of
bonds
3142
MIWireless Enable
Item Description
Identification ID in 2G or 3G.
Lats successful call duration
Last call status
Enables the Cloud Link 4G Modem pulse Counting
input. See Item 3113.
This item can be used to clear some logs or do a
firmware reset on Cloud Link. Writing to this
parameter is instantaneous and does not require
disconnecting from the instrument. 1 'Restore
Defaults-Device Config' - Similar to a factory
default done by shortening the pins. 7 'Restore
Defaults-Security Config' - Clears the SSL
certificate, issue time, expiry time,... 8 'Restore
Defaults-Battery Config' - Clears battery
configuration : battery type, battery change, ... 9
'Modem Reset' - Firmware reset. 10 'BLE Module
Reset' 11 'Restore Defaults-Internal Config'
Used when connecting to third party EVCs which
do not support Call Out start and end time. This
parameter can be used defines how long Cloud
Link will remain in server mode.
Units used when displaying the modem board
temperature (item 3114).
Number of devices which have paired with Cloud
Link. See item 3082.
0 = for 350 or integrated mode(default), 1 =
MiWireless. In MiWireless mode, the modem will
directly connect to the cellular network when the
power is applied. In EC350 or integrated mode,
once the power is applied to the modem, it will
Possible Values
Usigned integer 32
bits (in Sec)
0 - No Call, 1 - Call
in Init, 2 - Dialing,
3 - Dial Failed, 4 -
Connected, 5 -
Failed Due to No
Response, 6- PPP
Failed, 7 - TCP
Conn Failed, 8 -
Low Super Cap, 9 -
Invalid IP
Configuration, 10 -
Success.
0 - Disable, 1 -
Enable.
0 - None, 1 -
Restore Defaults-
Device Config, 2 -
Clear Event Logs, 3
- Clear Alarm Logs,
4 - Clear
Diagnostic Logs, 5
- Clear Cellular
Logs, 6 - Clear All
Logs, 7 - Restore
Defaults-Security
Config, 8 - Restore
Defaults-Battery
Config, 9 - Modem
Reset, 10 - BLE
Module Reset, 11 -
Restore Defaults-
Internal Config.
Unsigned Integer
32 bits Min = 60
Sec Max =
4294967295 Sec
String, 6 characters
0 - Degree Celcius,
1 - Farenheit, 2 -
Rankine, 3 - Kelvin.
Unsigned Integer 8
bits
0 - Disable, 1 -
Enable.
Honeywell