3.3.5.3 OPP Protection

1.
Use "
", "
shows.
2.
Use the numeric (
3.
Press "
" to confirm.
ENTER
4.
Press "
EXIT
" to return to the MAIN PAGE.
This function sets the protection point for Over Power. Once the output power exceeds the
range, it will turn off the output that is OUTPUT = OFF to protect the unit under test.
1.
62xxxH-xxx
2.
When OPP occurs the main page will prompt a protection message as Figure 3-69 shows:
" keys to move the cursor to the column to be set as Figure 3-68
Figure 3-68
0
9
~
) keys or "Rotary" (
Table 3-4 shows the power range of OPP.
Model
Min. OPP (W)
The OPP protection point is based on the comparison of calculated
power of output current and remote sense voltage.
Figure 3-69
) knob to set the value.
Table 3-4
0
1.05 x Po_MAX
Manual Operation
Max. OPP (W)
3-39