Where:
Cue# is a three digit ASCII value (000 to 999 or 000 to 399) that specifies the
cue location.
Time, StartTime and EndTime are 11 digit ASCII values that specifies
timecode values in the following format:
n1
and
n0
define play speed for the clip in CuePlyStop Slo mode. The
actual play speed is can be determined by the following equation.
TapeSpeed
These are the same values sent from the SloMoPro to a machine and are
defined on page 17 of the Sony document Protocol of Remote (9-pin)
Connector 2nd Edition.
The '
@
' character terminates the sending of cue data.
When sending data from a computer, a 30 mS delay must be inserted between
each cue to allow the SloMoPro to write to nonvolatile memory. The SloMoPro
performs this when it sends data.
For details on how to connect two SloMoPro controllers together or to connect your
SloMoPro to a computer, refer to the pinout section.
SloMoPro RS422 User Manual
hh:mm:ss:ff
n
n
1
2
32
0
10
=
+
256
43
n
1
n
+
1
1
2
32
32
10
10
×
2