Creating an Ethernet (LAN) Connection
This communication option enables using an Ethernet connection to connect the
inverter to the monitoring platform through a LAN.
Ethernet cable specifications:
Cable type – a shielded CAT6 Ethernet cable
Maximum distance between the inverter and the router – 100 m/ 330 ft.
NOTE
If using a cable longer than 10 m / 33 ft in areas where there is
a risk of induced voltage surges by lightning, it is recommend
to use external surge protection devices.
For details refer to:
http://www.solaredge.com/files/pdfs/lightning_surge_
protection.pdf.
To connect the Ethernet cable:
1. Remove the invertercover as described above.
2. Open Communication Gland 1.
CAUTION!
The gland includes a rubber waterproof fitting, which should be used to
ensure proper sealing.
3. Remove the plastic seal from one of the large openings.
4. Remove the rubber fitting from the gland and insert the CAT6 cable through the
gland and through the gland opening in the inverter.
5. Insert the cable through the opening in the Connection Unit towards the
communication board.
6. Push the cable into the cut opening of the rubber fitting.
CAT6 standard cables have eight wires (four twisted pairs), as shown in the diagram
below. Wire colors may differ from one cable to another. You can use either wiring
standard, as long as both sides of the cable have the same pin-out and color-coding.
SolarEdge Home Hub Inverter Single Phase MAN-01-00812-1.5
Chapter 7: Setting Up Communication with the Monitoring
Platform 57