Commissioning
You can then set the start addresses for inputs and outputs as well as the PROFIsafe parameters and
the standard module parameters.
–
In the configuration table, double-click the row of the output module CPX-FVDA-P2. The "Proper-
ties – FVDA-P2" dialogue window is displayed.
–
Now set the desired start addresses of the inputs and outputs on the [Addresses] tab of the dia-
logue window (è Fig.28).
2
1
Output module CPX-FVDA-P2 in the hard-
ware catalogue
2
Output module CPX-FVDA-P2 in the config-
uration table of the CPX terminal
Fig. 28 CPX terminal configuration with Siemens STEP 7 – HW Config
The third tab of the "Properties – FVDA-P2" dialogue window offers access to the standard parameters
of the output module.
Please note that not all of the PROFIsafe parameters that are represented here are relevant for the out-
put module. You can find detailed information about the individual parameters in
è 4.5.1 CPX module parameters for CPX-FVDA-P2 in detail.
Festo — CPX-FVDA-P2 — 2018-10b
3
3
Start addresses of the output module for
inputs and outputs (in this case, 44)
1
77