System overview CPX-FVDA-P2
Example 10 – permissible use of the CPX-FVDA-P2
Connecting output modules of a separate supply circuit via an additional supply to one of the two out-
put channels CH1 or CH2.
1
0 V
M CH1/2
VAL
24 V
P CH1/2
VAL
0 V CH1/2
+24 V CH1/2
FE CH1/2
1
Output channel CH1 or CH2 of output mod-
ule CPX-FVDA-P2
2
Additional supply CPX-M-GE-EV-Z...
Fig. 20 Connecting a separate supply circuit via an additional supply
NOTICE!
•
Only use the released output modules in the safety circuit.
•
Observe the specifications for connecting loads to an output module in the safety circuit
(è 2.4.2 Safety-related requirements and è Example 12 – permissible use of the CPX-FVDA-P2).
Festo — CPX-FVDA-P2 — 2018-10b
FE
24 V
OUT
24 V
OUT
24 V
EL/SEN
. . .
24 V
VAL
3
Part of the CPX terminal with the output
modules that must be switched off for
safety
0 V
OUT
2
3
51