Festo CPX-FVDA-P2 Original Instructions Manual page 70

Output module
Hide thumbs Also See for CPX-FVDA-P2:
Table of Contents

Advertisement

Commissioning
4.5
Setting the CPX module parameters
The characteristics of the output module CPX-FVDA-P2 can be parameterised. Parameters that influ-
ence diagnostic or error messages refer only to the diagnostic system of CPX and not to the diagnostic
channels of the safety protocol.
Further information on parameterisation can be found in the CPX system description for CPX-SYS-... or
the description of the bus node.
The following table provides an overview of the existing CPX module parameters of the output mod-
ule.
Overview of module parameters for CPX-FVDA-P2
Function number
1)
4828 + m * 64 + 0
4828 + m * 64 + 1 ... 5
4828 + m * 64 + 6
4828 + m * 64 + 7
4828 + m * 64 + 8 ... 21
4828 + m * 64 + 22
4828 + m * 64 + 23
1) Parameters read-only via operator unit and command interpreter (CI).
Tab. 30 Overview - module parameters for CPX-FVDA-P2
70
Bit
Module parameter
0, 1
Reserved
2
Supply voltage monitoring U
3 ... 7
Reserved
0 ... 7
Reserved
0
General diagnostics – output channel 0
1
General diagnostics – output channel 1
2
General diagnostics – output channel 2
3
Reserved
4
General diagnostics – module
5
General diagnostics – failsafe protocol
6, 7
Reserved
0
Wire break monitoring – output channel 0
1
Wire break monitoring – output channel 1
2
Wire break monitoring – output channel 2
3 ... 7
Reserved
0 ... 7
Reserved for PROFIsafe
0 ... 7
Setting of the DIL switch 0 ... 7
0, 1
Setting of the DIL switch 8, 9
VAL
Festo — CPX-FVDA-P2 — 2018-10b
Default
Active
Active
Active
Active
Active
Active
Inactive
Inactive
Inactive
1)
0