Activating Programming Mode
NOTE: If machine does not power up, check that both the Ground
Control Station - Emergency Stop Button, and the Plat-
form Control Console - Emergency Stop Button, are in the
RESET position.
Also if machine is equipped with the (PSL) Programmable
Security Lock option, see Section 3.5 of this Operators
Manual for additional machine power-up steps.
3121230
SECTION 5 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
– JLG Lift –
2
1
1. With machine power OFF, press and hold the Brake
Release Button (1) on the Ground Control Station.
2. While holding the Brake Release Button in, power machine
up by turning the Main Power Selector Switch (2), to either
the Ground Control or Platform Control Mode.
3. Release the Brake Release Button (1) after machine is pow-
ered up. The LCD display should now display five zeros,
one with a box around. Continue to next step Entering
Password.
5-17