SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION

General

The following conditions must be met before the machine can
be operated from the platform control console:
• Ground Control Station - Main Power Selector Switch must
be set to PLATFORM CONTROL MODE.
• Ground Control Station - Emergency Stop/Shut Down But-
ton must be in the RESET position (POWER ON).
NOTE: See Section 3.5 on page 3-7, for Ground Control Station
operation.
• Platform Console - On/Off Key Switch must be set to the ON
position.
• Platform Console - Emergency Stop/Shut Down Button
must be in the RESET position (POWER ON).
• If equipped with the OPTIONAL - PSL (Programmable Secu-
rity Lock - Section 3.12 on page 3-36) it must be set to the ON
position.
NOTE: SLEEP MODE - During operation if no control functions
have been activated for 10 minutes (default programma-
ble setting), the ground control module will power the
machine down to conserve battery power. Cycle power
back on using either the main power selector switch (key)
or the emergency stop/power down button on either the
platform controller or the ground control station.
3-16
Platform On/Off Key Switch
1
Set the ON/OFF Key Switch to the OFF position to power
machine down.
NOTE: If necessary, when machine is not in use, remove key from
platform key switch to disable machine from unauthor-
ized use.
NOTE: During operation the operator in the platform can prevent
unauthorized control of the machine (from the Ground
Control Station) by either switching the On/Off Key to the
OFF position, or activating the Emergency Stop Button on
the platform control console.
– JLG Lift –
At the Platform Control Console - Set
the On/Off Key Switch to the ON
position (2) to operate machine.
2
1. OFF Position
2. ON Position