Battery - Low Voltage Warning Indicators
The MVL/MSP Platform Control Console and Ground Control Station indicate battery low voltage at three (3) Warning Levels.
WARNING
LEVEL
PLATFORM CONTROL LED
LEVEL-1
LEVEL-2
LEVEL-3
NOTE:
(a) To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4 hours or until 8 bars are lit on the ground station LCD Display
before operating the machine. When drained to Warning Level 2 or 3, batteries must be charged until 8 bars are lit on the ground station LCD display to clear the fault code.
3121230
SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION
Table 3-1. Battery Low Voltage Warning Indicators.
INDICATOR LOCATION
GROUND CONTROL LCD
RESULT
• 3 LEDs/BARS Flashing with an audible
beep.
• Machine will Operate - No Control
Functions Locked Out.
• 2 LEDs/BARS Flashing with an audible
beep.
• Platform Lift-UP Function is Locked
Out.
• 1 LED/BAR Flashing with an audible
beep.
• Drive and Platform Lift-UP Functions
Locked Out.
– JLG Lift –
ACTION REQUIRED TO CLEAR FAULT
Charge batteries to a level of four (4)
LEDs/BARS or more before operating.
Charge batteries for a minimum of four
(4) continuous hours or eight (8) LEDs/
BARS lit before operating. (a)
Charge batteries for a minimum of four
(4) continuous hours or eight (8) LEDs/
BARS lit before operating. (a)