PLATFORM
FAULT
LEDS
CODE
FLASHING
4
3
6
8
13
6
17
7
32
7
33
2
3121230
SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION
Table 3-2. LCD Display - Operation Fault Conditions (Continued)
LCD SYMBOL SCREEN
00000.0
04
00000.0
1 3
00000.0
1 7
32
00000.0
00000.0
33
FAULT DESCRIPTION/
LCD TEXT SCREEN
MACHINE CONDITION
Tilt Condition
(Platform Elevated)
04
DRIVE and Lift UP Disabled
Drive Motor Brush Wear Warning (
25 hrs. of DRIVE operation remain-
ing to a 10 sec. shut down mode)
Traction Module
Over Temperature
13
(DRIVE Disabled)
Ground Control Module
Over Temperature
1 7
(Machine Stopped)
Pump Motor Over Current
(LIFT UP Disabled)
32
Both PHP Bars UP
DRIVE and Lift UP Disabled
33
– JLG Lift –
LOOK FOR THIS
Lower the Platform and Drive off
the Tilt Condition
Drive Motor Brushes Require Ser-
vice Replacement -
(See Section 5.5 on page 5-20 for
further Instructions)
Allow Drive System Traction Mod-
ule to Cool Before
Operating
Allow Ground Control
Module to Cool Before
Operating
Platform Load Over Capacity
Check for Object Blocking Both the
Left and Right PHP Bars
3-13