Oss Transducer Sensor Array Location; Oss Pre-Start Inspection - JLG 15MVL Operation And Safety Manual

Hide thumbs Also See for 15MVL:
Table of Contents

Advertisement

#6
#4
#2
Figure 3-9. OSS Transducer Sensor Array Location.
1. Transducer Arrays #1 through #6
2. Underside of MSP Platform
3121230
SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION
1
#5
#3
#1
2

OSS Pre-Start Inspection

(See Figure 3-10.)
From ground controls, raise platform approximately 5'-6' . The
RED LED on the electronic module will be illuminated when
power is applied. If an obstruction, such as a pad of paper is
placed under any of the transducer sensor arrays, the RED LED
will flash and remain flashing while the obstruction is present
and stop flashing 3 seconds after the obstruction is removed.
Check the operation of each transducer sensor array by placing
an object individually under each sensor array (within approxi-
mately 6"-12") and checking if the RED LED starts to "flash", and
stops flashing 3 seconds after the obstruction is removed. Also,
inspect the transducer arrays and electronic module for physical
damage, loose wires, loose mounting hardware, etc.
– JLG Lift –
3-39