Log sheet of programmed user functions

12

Log sheet of programmed user functions

Step
Function
1
Change the activated time of the control line 4
Change the function of control line 5
2
Change the flood time of control line 4
Change the flood time of control line 5
3
Change the function of contact 1
Change the function of contact 3
Change the function of contact 2
Change the function of LED 9 (remote transmission) and LED 6 (Fire alarm)
Change the function of control line 2
4
Change the function of monitored input 1
Suppress the fault indication if state "Released" is not reported
Change the function of monitored input 2
5
Change the active mode of control line 1
Change the active period of control line 1
Change the active mode and active period of control line 3
6
Enable "Alarm Verification" function of detector zones 1 and 2
Enable "Alarm Verification" function of detector zone 3
Enable "Alarm Verification" function of detector zones 4
7
Deleted
Deleted
Deleted
8
Change the function of monitored input 3
Suppress "Reset" upon "stopped activated time by monitored Input 3"
Change the fault processing of the monitored input 3
9
Change the reaction after "Reset" of the detector zones 1 and 2
Change the reaction after "Reset" of the detector zone 3
Change the reaction after "Reset" of the detector zone 4
Change the reaction after "Reset" of the monitored Input 1
Interlock the "Reset" function if executed via control input 1
Interlock the "Reset" function
10
Change the indication of the blocking states
Change active mode of indicator "Released"
11
Change the function of detector zones 1 and 2
Change the line fault processing of the detector zones 1 and 2
Change the function of detector zone 3
12
Change the basic code for Access Level 2
Change the access level for the function "Silence Buzzer"
13
Change the processing of "Fire alarm condition"
Change the function of the key "Silence buzzer"
Enable the function "Reminder Beep"
Enable the function "Fault to be Reset"
Enable the function "RT-Alarm + RT Fault suppressed on Access Level 2"
Enable the function "Reset via control input 1 suppressed upon state RT-Alarm"
Suppress the "battery fault"
Change the active mode of the buzzer in state "Emergency hold/abort"
14
Change the fault delay in the event of mains failure
15
Change the function of control input 2
Change the function of control input 3
Change the function of control input 4
16
Change the function of driver output 2
Change the function of driver output 8
Change the function of driver output 1
90
Building Technologies
Fire Safety & Security Products
Installation: ..................................................................................................................
Option,
Option,
default
individual
7
14
1
6
1
5
8, 10
12, 15
17
1
4
6
1, 5, 9
11
15, 18, 20
1
3
5
1
1
7, 9
7, 9
11
11
1
8
10
1
3
6
8
10
11
1
3
1
6
9
1
4
1
3
5
7
9
11
13
15
3
1
8
15
1, 9
10, 18
20
A6V10099837_a_en
12.2007

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents