6400-Lu1-Scs-Remote Sna 3174 Control Unit - IBM 6400i Setup Manual

Line matrix printers, cabinet and pedestal
Table of Contents

Advertisement

Appendix D
Attaching Printer to zSeries Systems

6400-LU1-SCS-Remote SNA 3174 Control Unit

LU1-SCS mode is utilized when neither IPDS nor PSF is needed to
accomplish the print function desired. An existing remote 3174 SNA-
connected control unit is assumed. The steps required to install a remote
LU1-SCS printer for host definitions are as follows:
1. Define to NCP, point to LU1 logmode entry defined below
2. Define to VTAM by adding logmode entry to VTAM Logmode Table
3. Define to JES2 (May not required if VPS. See details below)
4. Define to JES328X Print Facility, VPS, or equivalent product.
5. Select the options on the printer that are appropriate for the environment.
Step 1 - NCP Definition
XYZ
LINK
REMPU74 PU
REM6400 LU
Step 2 - VTAM Definition
* The following entry should be placed in the VTAM MODE TABLE specified
above or another of your choice.
6400SCSR MODEENT LOGMODE=6400SCSR,
FMPROF=X'03',TSPROF=X'03',PRIPROT=X'B1',
SECPROT=X'90',COMPROT=X'3080',RUSIZES=X'87C6',
PSERVIC=X'01000000E100000000000000',
PSNDPAC=X'01',SRCVPAC=X'01'
318
GROUP
TYPE=NCP,...
ADRESS=(032),...
ADDR=C1,...
LOCADDR=#,(# replaced by port on control unit)
DLOGMOD=6400SCSR,(Default LOGMODE ENTRY NAME)
MODETAB=MYTABLE (Table name containing MODEENT)*