6
Fault Messages
Fault Message
046 EC STOPPED AT
STATE
<state>
056 HAMMER COIL OPEN
057 CLOSE PLATEN
058 SHUTTLE JAM
SEE SETUP GUIDE
059 CANCEL PRINT
ACTIVE
060 PRINTER HOT
062 EXHAUST FAN FAULT
280
Table 12: Fault Messages
Operator
Explanation
Correctable?
No
Controller self–test and
initialization sequence
was halted at <state>,
where <state> is one of
10 numerically coded
messages.
No
Electrical malfunction of
one or more hammer
coils.
Yes
Forms thickness lever is
raised to the open
position.
No
No shuttle movement or
the shuttle is moving at
the wrong speed.
N/A
Non–error status
message.
No
Controller board sensors
report high temperatures
on the board.
Yes
Sensors cannot detect
current in fan circuit.
Solution
Contact your IBM service
representative.
(You can continue to print
with degraded print
quality.) Contact your IBM
service representative.
Lower the forms thickness
lever.
Make sure the ribbon is not
twisted and the forms
thickness lever is set
correctly. If the fault
reoccurs, contact your IBM
service representative.
No action necessary.
Contact your IBM service
representative.
Power off the printer.
Check for obstruction of
vents and fan airway;
remove any obstructions.
Check for items beneath
the printer blocking cabinet
vents. Power back on the
printer. If this message
reoccurs, contact your IBM
service representative.
NOTE: This message
should not appear on a
Pedestal model. If this
message does appear,
contact your IBM Service
Representative.