IBM 6400i Setup Manual page 278

Line matrix printers, cabinet and pedestal
Table of Contents

Advertisement

Chapter
6
Fault Messages
Fault Message
022 UNIT ADDRESS NOT
RECEIVED
CHECK PRINTER
ADDRESS
024 SERIAL LINE PARITY
ERROR
VERIFY CONFIGURATION
025 SERIAL FRAMING
ERROR
VERIFY CONFIGURATION
026 HEX DUMP MODE
027 COMMUNICATIONS
CHECK
CALL SYSTEM OPERATOR
028 COMMUNICATIONS
CHECK
CALL SYSTEM OPERATOR
029 8344 DIAGNOSTIC
TEST FAILED
031 END OF FORMS
TIMEOUT
LOAD FORMS
032 FORMS JAMMED
TIMEOUT
CLEAR JAM AND RELOAD
FORMS
278
Table 12: Fault Messages
Operator
Explanation
Correctable?
Yes
Unit address not
recognized by printer.
(Poll timeout, twinax
interface)
Yes
Parity error. (Serial
interface)
Yes
Framing error. (Serial
interface)
N/A
Printer attach status
message.
Yes
Enable poll timeout. The
printer was not enabled
for one minute. (Coax
interface)
Yes
Poll timeout error. The
printer was not polled for
one minute. (Coax
interface)
No
Link–level code test
detects hardware failure.
Yes
A timeout message is
sent to the host if paper
is not loaded 10 minutes
after Stop was pressed
to clear the paper out
fault.
Yes
A timeout message is
sent to the host if no
paper motion has
occurred for 10 minutes
after Stop was pressed
to clear the jam fault.
Solution
Ensure that printer address
matches host setting.
Check printer serial port
configuration setup.
Ensure that parity setting
matches both host and
printer settings.
Check printer serial port
configuration setup.
Ensure that it matches host
setting.
No action necessary.
Check cable connection
and host system.
Check cable connection
and host system.
Contact your IBM service
representative.
Load paper. Refer to the
Setup Guide for
procedures.
Clear paper jam and reload
paper. Refer to the Setup
Guide for procedures..