6500-LU1-SCS-Remote SNA 3174 Control Unit

LU1-SCS mode is utilized when neither IPDS nor PSF is needed to accomplish the
print function desired. An existing remote 3174 SNA-connected control unit is
assumed. The steps required to install a remote LU1-SCS printer for host
definitions are as follows:
1. Define to NCP, point to LU1 logmode entry defined below
2. Define to VTAM by adding logmode entry to VTAM Logmode Table
3. Define to JES2 (May not required if VPS. See details below)
4. Define to JES328X Print Facility, VPS, or equivalent product.
5. Select the options on the printer that are appropriate for the environment.
Step 1 - NCP Definition
XYZ
GROUP
LINK
ADRESS=(032),...
REMPU74 PU
REM6500 LU
DLOGMOD=6500SCSR,(Default LOGMODE ENTRY NAME)
MODETAB=MYTABLE (Table name containing MODEENT)*
Step 2 - VTAM Definition
* The following entry should be placed in the VTAM MODE TABLE specified
above or another of your choice.
6500SCSR MODEENT LOGMODE=6500SCSR,
FMPROF=X'03',TSPROF=X'03',PRIPROT=X'B1',
SECPROT=X'90',COMPROT=X'3080',RUSIZES=X'87C6',
PSERVIC=X'01000000E100000000000000',
PSNDPAC=X'01',SRCVPAC=X'01'
TYPE=NCP,...
ADDR=C1,...
LOCADDR=#,(# replaced by port on control unit)