FSCA-01 configuration parameters – group C (group 3)
Note: The actual parameter group number depends on the drive
type. Group C (group 3) corresponds to:
parameter group 54 in ACS355
parameter group 52 in ACSM1, ACS530, ACS850 and
ACQ810
parameter group 52 in ACS880 if the adapter is installed as
fieldbus adapter A or group 55 if the adapter is installed as
fieldbus adapter B.
1)
No.
Name/Value
01
FBA data in1
(drive to master)
0 = None
101...9999
Other
02...
FBA data in2...
12
FBA data in12
1)
The number of parameters in this group may vary by drive type and drive firmware.
Description
Selects the drive parameter address from
which the data is read to the DATA IN 1
register (from the server to the master). The
Modbus register address maps are explained
in chapter
Communication
The content is defined by a decimal number in
the range of 0 to 9999 as follows:
0
Not used
1...99 Virtual address area of drive control.
Not used with Modbus/RTU.
101...
Parameter area of the drive
9999
Not used
Parameter index with format xxyy, where
xx is the parameter group number (1...99)
yy is the parameter number index within
that group (01...99).
Path to parameter area selection.
See parameter
01 FBA data
Start-up 43
protocol.
in1.
Default
0 = None
0 = None