64 Modbus/TCP – Start-up
FENA-01/-11/-21 configuration parameters – group B (group 2)
Note: The actual parameter group number depends on the drive
type. Group B (group 2) corresponds to:
parameter group 55 in ACS355
parameter group 53 in ACSM1, ACS380, ACS480, ACS580,
ACS850 and ACQ810.
parameter group is typically 53/56 (group 153/156 in some
variants) in ACS880 and ACS880-M04 if the adapter is
installed as fieldbus adapter A/B.
1)
No.
Name/Value
01
FBA A/B data out1
(client to drive)
0 = None
101...9999
02...
Data out 2 ...
12
Data out 12
1)
The number of parameters in this group may vary by drive type and drive firmware.
Description
Selects the drive parameter address into which
the value of the Data out 1 register is written
(from the client to the server). The Modbus
register address maps are explained in chapter
Modbus/TCP – Communication
The content is defined by a decimal number in
the range of 0 to 9999 as follows:
0
Not used
1...99 Virtual address area of drive control.
Not used when the Modbus/TCP
protocol is used.
101...
Parameter area of the drive
9999
Not used
Parameter index with format xxyy, where
xx is the parameter group number (1...99)
yy is the parameter number index within
that group (01...99).
Note: In ACS480, ACS580 and ACS880,
choose Other to display a list of mappable
drive parameters.
See parameter
01 FBA A/B data
Default
0 = None
protocol.
out1.
0 = None