European CE certification

The radio modem has been approved for operation under the RTT&E directive, passing the following tests: ETS300-
826 (EMC), ETS300-328 (Functionality), and EN60950 (Safety).
The following is the appropriate label that is applied to the radio modem product line to indicate the unit is approved
to operate with CE certification:
The following is the appropriate label that is applied to the radio modem product line shipping package to indicate the
unit is approved to operate with CE certification:
AUS
B
DK
F
D
GR
I
LUX
NL
E
S
UK
Note: Member states in the EU with restrictive use for this device are crossed out. This device is also authorized for
use in all EFTA member states (CH, ICE, LI, and NOR).
IMPORTANT: This device is a 2.4-GHz, low-power RF device intended for office and home use in all EU and EFTA
member states, except in France where restrictive use applies.

EU Requirements

1. For outdoor use, France has a frequency restriction of 2.4GHz - 2.454GHz for an output power greater than 10mW
and below 100mW.
2. For outdoor use in France, the output power is restricted to 10mW in the frequency range of 2.454GHz –
2.4835GHz.
3. 5.15GHz – 5.35GHz is restricted to 200mW EIRP throughout the European Union.

RLXIB: Power over Ethernet Injector and Accessories Warning

The PoE Injector was not a part of the hazardous location or ATEX certification. Therefore, if an injector is used to
power any of the radios, the PoE injector must be installed/located outside of any area that could be known to be
hazardous. The AC power adaptor was not a part of the haz loc certification.
The RLXIB series were tested and certified to hazardous location and ATEX without any accessories included in this
certification. Therefore, any accessory added to the RLXIB series radios must be used in an area known to be non-
hazardous as they have not been subjected to hazardous location and ATEX certifications.
The preferred method of powering the radios is using the supplied power adaptor but If the PoE injector is used in an
ordinary location "only", the PoE injector must be Listed. If the PoE injector is used instead of the supplied power
adaptor, all of the wiring to and from the injector must be routed/installed inside building/plant and never
routed/installed outside of the building/plant.
Locations & Use
The Industrial HotSpot radios, such as the RLXIB-IHW are used by professionals in Industrial
Applications/installations only and not used by the general consumer. These industrial radios are used for industrial
applications such as, water treatment facilities, power plants, factories, railroads, remote oil/gas pipelines, refineries,
cargo ships, refueling ships etc....and used for wireless high speed data transmission. All radios are installed and