Antenna spacing requirements for user safety
It is important to keep the radio's antenna a safe distance from the user. To meet the requirements of FCC part
2.1091 for radio frequency radiation exposure, this radio must be used in such a way as to guarantee at least 20 cm
between the antenna and users. Greater distances are required for high-gain antennas. The FCC requires a
minimum distance of 1 mW *cm2 power density from the user (or 20 cm, whichever is greater).
If a specific application requires proximity of less than 20 cm, the application must be approved through the FCC for
compliance to part 2.1093.
The installer of this radio equipment must ensure that the antenna is located or pointed in such a way that it does not
emit RF fields in excess of Health Canada limits for the general population; refer to Safety Code 6, obtainable from
Health Canada.
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the
equivalent isotropically radiated power (EIRP) is not more than that required for successful communication.
Regulatory Approvals
Wireless Approvals
Visit our web site at www.prosoft-technology.com for current wireless approval information.
Hazardous Locations
UL
cULus
CSA/UL
ATEX
RLXIB: ATEX Approval
II 3 G
II 3 G
Ex nA nL IIC T6 X
-30C° <= Ta <=60°C
ProSoft Technology, Inc., Bakersfield, CA USA
Model: RLXIB
S/N: XXXXXXXXXX
Caution:
Read instructions before operating in Hazardous Areas
N. America
The Radio must be installed inside an IP54 enclosure which requires a special tool for access.
Product name: RLXIB
Safety Warning Statements
Explosive Atmosphere
Power, Input, and Output (I/O) wiring must be in accordance with the authority having jurisdiction
A
Warning – Explosion Hazard – Do not make or break connections in an explosive atmosphere.
B
Caution – Use only approved recommended power supply.
C
Warning - Power supply should be installed in a non-hazardous area.
D
Warning – DO NOT OPEN WHEN ENERGIZED.
E
These products are intended to be mounted in an IP54 enclosure. The devices shall provide external means to
prevent the rated voltage being exceeded by transient disturbances of more than 40%. This device must be used
only with ATEX certified backplanes.
ANSI/ISA 12.12.01 Class I, Division 2, Groups A, B, C, D
C22.2 No. 213-M1987
ANSI/EN60950-1
EN60079-0/-15 Zone 2 Category 3