Functions
6.2 Inverter Control
6.2.5

Three-wire control, method 1

Function description
● The first control command is a permanent enable signal for starting the motor. When this
enable signal is canceled, the motor stops.
● CW rotation is activated with the positive edge of the second control command.
● CCW rotation is activated with the positive edge of the third control command.
Image 6-5
Table 6- 9
Enable
signal
Table 6- 10
Parameter
P0700 = 2
P0727 = 2
P0701 = 1
P0702 = 2
P0703 = 12
100
Three-wire control using digital inputs, method 1
Function table
Motor ON /
CW
0
Not relevant
1
0→1
1
0
1
0
1
1
Parameterizing the function
Description
Controls the motor using the digital inputs of the inverter
Three-wire control, method 1
The enable signal to power-up the motor is issued with digital input 0
Further options: The enable signal can be issued with any other digital input, e.g. with
digital input 3 via P0704 = 1
CW rotation is activated with digital input 1
Further options: CW rotation can be activated with any other digital input, e.g. with
digital input 3 via P0704 = 2
CCW rotation is activated with digital input 2
Further options: CCW rotation can be activated with any other digital input, e.g. with
digital input 3 via P0704 = 12
Motor ON /
Function
CCW
Not relevant
OFF1: The motor decelerates to a standstill
0
The motor accelerates to the setpoint
0→1
The motor accelerates to the inverted setpoint
0
No effect on the direction of rotation.
1
OFF1: The motor decelerates to a standstill