Premium Delayed Egress
PED4000 D, PED5000 D Series Exit Device
Installation Instructions
4

Device Mounting

1. Refer to installation instructions included with device and trim for complete door and frame preparations. Refer to
template for wire access hole location.
2. Feed wires from power transfer through wire access hole in door. (Figure 4)
ElectroLynx System Default Wiring Options for DEED QC12 Hinge (12 wires)
VDC
RR
EI
DS
(RAR COM)
8, Yellow (RAR NC)
(SEC COM)
4, Tan (SEC NO)
ElectroLynx Field
Wiring Termination
Options
(12 wires max)
QC12 Hinge
QC12 Hinge Pigtail
or
15' Frame Harness
NOTES:
Wires must be protected from abrasion.
For use with Class II circuits only.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without
the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Pluggable 8-pin & 4-pin connectors . Default wiring shown .
QC12 Hinge
QC12 Hinge Pigtail
or
15' Frame Harness
Premium Delayed Egress
Device
Door Harness
3" Typical
Pluggable 8-pin and
4-pin connectors
Door Harness
3" Typical
Rail to Hinge Harness
(with 8-pin, 4-pin, & 26-pin connectors )
8-pin
6 4
2
8
7
5
3
1
RR
(EI)
DS
(RAR COM)
8, Yellow (RAR NC)
4-pin
2
4
3
1
(SEC COM)
4, Tan (SEC NO)
Figure 4
8
Premium Delayed Egress
Rail Assembly
Must connect to metal tab
on exit device end bracket
26-pin
FM574 01/23