1. Installation
Additional power supply
Plugs
2
3
4
1 2 3 4 5
V
: Load voltage for outputs
OUT
Tab. 1/8:
Pin allocation: Additional power supply for outputs

1.5.2 Sealing unused connections in the Rugged Line plug

1-28
The outputs are supplied with load voltage via the
interlinking blocks with additional power supply
CPX-M-GE-EV-Z-7/8-5POL or CPX-M-GE-EV-Z-PP-5POL.
Pin assignment for additional power supply
Additional power supply type CPX-M-GE-EV-Z-7/8-5POL
1
1: 0 V
Out
2: Unused
5
3: FE
Additional power supply type CPX-M-GE-EV-Z-PP-5POL (Push Pull)
1: Not connected
2: Not connected
3: 24 V
Out
Note
Seal unused connections in the Rugged Line plug.
Use only sealing rubber which has not been broken
through.
You can then be sure of complying with protection class
IP65/67.
4: Unused
5: 24 V
Out
4: 0 V
Out
5: FE