5. Maintenance and conversion
5.8
Converting the CPV valve terminal to a version with different electri-
cal connections
Festo P.BE-CPV-EN en 0005e
Due to the modular structure of the CPV valve terminal, you
can easily convert it to IC, MP, AS-i, DI or CP connections.
Please note
Please note the instructions in the compatibility list in this
chapter as regards combining versions with different elec-
trical connections with the following plates:
– Single-solenoid 5/2-way valve (Ident.code F)
– Relay plates (Ident.code R).
Proceed as follows
CPV valve terminals with IC connection
S
Loosen the locking screws on the connector sockets.
S
Pull the socket and, if necessary, the intermediate plug
carefully away from the terminal lugs of the pilot sole-
noids.
S
Insert the MP, AS-i, DI or CP connection onto the terminal
lugs of the pilot solenoids.
S
Secure the sub-base with the 4 Philips screws. Tighten
the screws in diagonally opposite sequence.
5-23